{"id":42,"date":"2025-07-04T13:50:30","date_gmt":"2025-07-04T11:50:30","guid":{"rendered":"http:\/\/www.koerner-laser.de\/wordpress\/?page_id=42"},"modified":"2025-07-08T12:04:50","modified_gmt":"2025-07-08T10:04:50","slug":"beam-profiling-solutions","status":"publish","type":"page","link":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/beam-profiling-solutions\/","title":{"rendered":"Beam Profiling Solutions"},"content":{"rendered":"\n<figure class=\"wp-block-image aligncenter size-full has-custom-border mit-schatten\"><img loading=\"lazy\" decoding=\"async\" width=\"911\" height=\"560\" src=\"https:\/\/www.koerner-laser.de\/wordpress\/wp-content\/uploads\/2025\/07\/ubp-lineup.jpg\" alt=\"KLT-UBP2-160 lineup\" class=\"wp-image-101\" style=\"border-style:none;border-width:0px;border-radius:47px\"\/><figcaption class=\"wp-element-caption\">Lineup of different KLT-UBP2-160 beam profilers<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n\n\n<p>Our range of beam profilers offers a unique thermal detection scheme, that allows the measurement of any kind of laser beam at any wavelength. Recent improvements in the detector surface technology significantly improve the sensitivity and added a specialized detector surface for the use with CO<sub>2<\/sub> lasers around 10.6\u00b5m.<\/p>\n\n\n\n<p>Our detection technology is unique amongst laser beam profilers and comes with a bunch of advantages in comparison to other beam profilers:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>high data depth of ca. 14Bit<\/li>\n\n\n\n<li>direct measurement of up to approximately 0.5W\/cm\u00b2 (no attenuators)<\/li>\n\n\n\n<li>the robust detector surface can withstand up to ~0.5J\/cm\u00b2 with 10ns pulses<\/li>\n\n\n\n<li>if you should manage to damage the detector surface, it can be exchanged at a budget as the detector itself will not be harmed<\/li>\n<\/ul>\n\n\n\n<p>Depending on your needs we offer a range of different detector sizes and resolutions. Besides the standard sizes also large detector surfaces up to 300mm (diagonal)&nbsp; and higher resolutions are available on request.<\/p>\n\n\n\n<p>The included software is accessible with a standard browser via network connection on any device (smartphone, tablet, PC) and covers your beam profiling needs: e.g. different false color schemes, line-outs, triggering, averaging, beam evaluation (power and size) and saving raw and processed data. In combination with our separately available M\u00b2-measurement add-on, a complete fully automated M\u00b2-measurement is possible.<\/p>\n\n\n\n<p>Additionally, for the models with a resolution of 320x256pixels and above a 7\u201c touchscreen with the same user interface is included (for the KLT-UBP2-160 this is optionally available).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications (standard versions)<\/h2>\n\n\n\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1 klt-ubp2-techspec-table tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">KLT-UBP2-160<\/th><th class=\"column-3\">KLT-UBP-HR2-320<\/th><th class=\"column-4\">KLT-UBP-HR2-640<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">resolution<\/td><td class=\"column-2\">160&#215;120 pixels<\/td><td class=\"column-3\">320&#215;256 pixels<\/td><td class=\"column-4\">640&#215;512 pixels or <br \/>\n640&#215;480 pixels*<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">pixel size<\/td><td colspan=\"3\" class=\"column-2\">ca. 100\u00b5m**<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">spectral sensitivity range<br \/>\n<\/td><td colspan=\"3\" class=\"column-2\">standard: 190nm\u20265\u00b5m<br \/>\nCO2 version: ca.10.6\u00b5m***<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">max. acquisition rate<\/td><td class=\"column-2\"><9Hz<\/td><td colspan=\"2\" class=\"column-3\">60Hz<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">trigger options<\/td><td colspan=\"3\" class=\"column-2\">free run, software trigger, external trigger<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">interface<\/td><td class=\"column-2\">wlan, ethernet<br \/>\noptional 7\u201d touchscreen<\/td><td colspan=\"2\" class=\"column-3\">wlan, ethernet<br \/>\n7\u201d touchscreen<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">sensitivity<\/td><td class=\"column-2\">up to ~20 pixel counts per mW\/cm\u00b2<\/td><td colspan=\"2\" class=\"column-3\">up to ~100 pixel counts per mW\/cm\u00b2<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">noise level<\/td><td class=\"column-2\"><0,2mW\/cm\u00b2<\/td><td colspan=\"2\" class=\"column-3\"><0,1mW\/cm\u00b2<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td colspan=\"4\" class=\"column-1\">* depending on chipset<br \/>\n** variation possible on request<br \/>\n*** sensitivity may differ from standard version<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache -->\n\n\n<h2 class=\"wp-block-heading\">Software<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"480\" src=\"https:\/\/www.koerner-laser.de\/wordpress\/wp-content\/uploads\/2025\/07\/control-software.jpg\" alt=\"\" class=\"wp-image-106\"\/><figcaption class=\"wp-element-caption\">Image of beam profiler software as displayed on 7&#8243; touchscreen with lineout and beam evaluation enabled<\/figcaption><\/figure>\n\n\n\n<p>A key to the ease of use of our profiler software is the included software. All versions incorporate a webserver for accessing the software. The server can be accessed via wireless lan or wired connection. When connected all it needs is a browser to access the user interface. The interface features a broad range of features, that should cover most needs:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>live image with &gt;25 false color overlays<\/li>\n\n\n\n<li>scaling options<\/li>\n\n\n\n<li>horizontal and vertical line-outs<\/li>\n\n\n\n<li>trigger control<\/li>\n\n\n\n<li>beam evaluation (following ISO 11146-1), center of gravity and power estimation<\/li>\n\n\n\n<li>averaging, background subtraction<\/li>\n\n\n\n<li>various image improvement algorithms<\/li>\n\n\n\n<li>possibility to save raw data or image as displayed<\/li>\n<\/ul>\n\n\n\n<p>Furthermore, the software is constantly improved and updates are deployed for free on existing beam profilers (if compatible). Therefore, if you should miss a functionality, please let us know and the chances are good, that your requested functionality will be added by a future update!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Add-ons<\/h2>\n\n\n\n<p>We offer a range of custom add-ons to our beam profilers ranging from attenuators and fixed telescopes setups but also an automatic M\u00b2-measurement measurement system that is integrated in the beam profiler&#8217;s software.<\/p>\n\n\n\n<p>The M\u00b2 measurement system includes a motorized stage with a zig-zag beam path and calcium fluoride optics maintaining the broad band capability of the beam profiler. After connecting the M\u00b2 measurement system to the beam-profilers control unit, it is automatically recognized and new software options for M\u00b2 measurement are available.<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"427\" src=\"https:\/\/www.koerner-laser.de\/wordpress\/wp-content\/uploads\/2025\/07\/M2.png\" alt=\"M2 measurement add-on\" class=\"wp-image-93\" style=\"object-fit:cover\"\/><figcaption class=\"wp-element-caption\">M\u00b2 measurement add-on<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"715\" height=\"427\" src=\"https:\/\/www.koerner-laser.de\/wordpress\/wp-content\/uploads\/2025\/07\/M2-control-1.png\" alt=\"\" class=\"wp-image-95\" style=\"object-fit:cover\"\/><figcaption class=\"wp-element-caption\">beam profiling software with M\u00b2 measurement<\/figcaption><\/figure>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Customization Options<\/h2>\n\n\n\n<p>Besides the standard versions of our profiler we could supply you with modified versions adapted for your needs. Possible variations would be e.g. a large detector surface up to approximately 300x200mm\u00b2 or higher resolutions up to 1280&#215;1024 pixels. Please feel free to <a href=\"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/contact\/\" data-type=\"page\" data-id=\"28\">contact us<\/a> if you need anything special.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"482\" src=\"https:\/\/www.koerner-laser.de\/wordpress\/wp-content\/uploads\/2025\/07\/large-Profiler-CO2.jpg\" alt=\"\" class=\"wp-image-104\"\/><figcaption class=\"wp-element-caption\">Customized version of KLT-UBP-HR2-320 with extra large detector area (ca. 6,4&#215;5,1cm\u00b2) for CO<sub>2<\/sub> laser detection.<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Overview Our range of beam profilers offers a unique thermal detection scheme, that allows the measurement of any kind of laser beam at any wavelength. Recent improvements in the detector surface technology significantly improve the sensitivity and added a specialized detector surface for the use with CO2 lasers around 10.6\u00b5m. Our detection technology is unique [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-42","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/pages\/42","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/comments?post=42"}],"version-history":[{"count":12,"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/pages\/42\/revisions"}],"predecessor-version":[{"id":218,"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/pages\/42\/revisions\/218"}],"wp:attachment":[{"href":"https:\/\/www.koerner-laser.de\/wordpress\/index.php\/wp-json\/wp\/v2\/media?parent=42"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}